homepage Product center Atlas Air Compressor Bolet air compressor Air post-treatment equipment Air compressor application list Air compressor encyclopedia About us Contact us

Atlas Copco air compressor 0512-62910301

Company headquarters: Suzhou high-tech Zone Liangang Road Shanghai Marketing: Baosheng Road, Songjiang District, Shanghai Factory address: Changjiang Road, Xinwu District, Wuxi City Telephone consultation, regional personnel will be arranged to contact

What are the reasons for the high-temperature shutdown of screw air compressors?

作者: Bolet air compressor 时间:2023.06.09 Number of page views: 1404

With the recent increase in temperature, we often receive customer feedback after sales: my air compressor is hotHigh temperature shutdownWhat is the reason?Is there something wrong with the quality of your air compressor?Today, Xiaobian has organized the following content on this issue:

First, external environmental factors

In general, a large part of the reason for the high temperature stop of the air compressor is that the air compressor is placed improperly: there is a heat source around the machine, it is too close to the wall or other obstacles, the machine room is not ventilated, and the front door and side door are opened during the operation of the equipment,The fan fails to form convection,These will cause the air compressor exhaust is not smooth, resulting in the air compressor temperature is too high

Two, air compressor parts failure

1. Abnormal temperature control valve

The access valve beside the temperature control is open。When the unit is on, the cooling oil will flow directly back into the head, and will not pass through the radiator and cause the air compressorHigh temperature shutdown

2. The fan blade is faulty

The fan blades are broken or loose, which affects heat dissipation and causes device problemsHigh temperature shutdown

Air compressor

3, oil cut-off valve failure

The oil cut-off valve is generally available on a relatively large machine, and after failure, the temperature rises rapidly because it cannot be cooled。

4, cooling oil is not enough

Lack of cooling oil should be added in time, otherwise it will affect the cooling effect。

5. Dirt of the oil filter

There is pollution 洉 in the oil filter, the amount of oil entering it will be reduced, and there will be a certain resistance, and the screw air compressor will not reach the lubrication effect due to the lack of oil。

6, oil and gas separator filter element stains too much

When the filter element of the oil and gas separator of the screw air compressor is too dirty, the oil will slow down in the process of circulating flow, causing the air compressorHigh temperature shutdown

7. The radiator is blocked

The compressor works in a dusty environment for a long time, and after a certain period of use, there will be a layer of dirt on the surface of the radiator, and the interior will also form a blockage, which is easy to cause poor heat dissipation。

Above isAtlas Bolet compressorSmall series of air compressor shutdown fault related content, I hope to help you!

Previous post:What is the difference between air compressor lubricating oil and grease?
Next post:Select the right compressed air to ensure food safety
homepage Atlas Air Compressor Bolet air compressor Air post-treatment equipment Atlas Copco Shanghai Bolet compressor Air compressor maintenance